Werk #6189: OpenHardwareMonitorCLI did not run on some Win7 machines
Component | Checks & agents |
Title | OpenHardwareMonitorCLI did not run on some Win7 machines |
Date | May 25, 2018 |
Checkmk Edition | Checkmk Raw (CRE) |
Checkmk Version | 1.5.0b6 1.6.0b1 |
Level | Trivial Change |
Class | Bug Fix |
Compatibility | Compatible - no manual interaction needed |
OpenHardwareMonitorCLI, the executable wrapper for triggering OpenHardwareMonitor by Check_MK Windows Agent, did not run on some Win7 machines. Moreover, it was not possible to compile OpenHardwareMonitorCLI with versions 4.x of Mono (tried with Mono 4.6.2.0 / XBuild 14.0). Providing the build option /p:TargetFrameworkVersion="v4.5" both fixed the build with Mono 4.x and made resulting executable compatible with all tested Windows versions (tested on Win7 and Server 2016).