Adva FSP 3000 Optical Transport: Temperature

Distribution: official part of Check_MK
License: GPL
Supported Agents: SNMP

This checks monitors the

- temperature of ports

- temperature of modules

- temperature trends

of the Adva FSP 3000 scalable optical transport solution.

No default limits are set for the temperature, since limits are configured in thedevice itself. The upper and lower limits for the temperature are read from the device.

The threshold for

- temperature increase

- time range

- time period

can be manually configured.

If the current value is outside the allowed range the service goes CRIT, otherwise it is OK.

If the rate of temperature increase is above the rate per time range, the service goes WARN or CRIT, depending on the rate.

The check can also predict in which period of time the upper limit for the temperature on the device will be reached and goes WARN or CRIT if this time period is shorter than the configured one.

This check uses the FspR7-MIB.

Item

Name of the module or port.

Discovery

One service is created for each connected temperature sensor on all modules/ports