Check manual page of genua_state_correlation
Genua: Correlation of the State of Carp Interfaces
Distribution: | official part of Check_MK |
License: | GPL |
Supported Agents: | SNMP |
This check monitors if the two or more carp interfaces found on genuscreen
devices have the same carp state. If not, the check is critical.
The check is known to run with genuscreen version 3.0 and 4.1, supports
genuas regular enterprise id 3717 as well as the id 3137 which was
introduced in a bug in some versions of genuscreen.
Discovery
The inventory process checks if the device has a system description OID of .1.3.6.1.2.1.1.2.0 and if the name of this OID contains "genuscreen", "genuscript" or "genubox" (case insensitive). If this is true and at least two carp interfaces are found, then the system is inventorized.