Check-Manual von dell_poweredge_amperage_power

Dell PowerEdge Server: Power Consumption

Distribution Official part of Checkmk
Lizenz GPLv2
Unterstützte Agenten SNMP
This check monitors the power consumption of power units of Dell PowerEdge Servers.

No limits are set in the check, since limits are configured in the device itself. The state given by the device is taken as the state of the check as follows: If the device returns OK, the check is OK. If the device returns other, unknown, nonCriticalUpper and nonCriticalLower a state of WARN is returned. Otherwise the check is CRIT.

The check displays the upper warning and critical limits as configured in the device. Further limits are not displayed, even though they may be configured. These are UpperNonRecoverable, LowerCritical, LowerNonCritical and LowerNonRecoverable. These limits yet may lead to state changes, the corresponding states are honoured as outlined above.

Item

The name of the location variable configured for the power unit

Discovery

One service is created for each power unit.