This check provides information about the power supply unit (PSU) of an UCS C-Series Rack Server. This main check provides info about the PSU overall operability status. The sub check ucs_c_rack_server_psu.voltage provides info about the PSU voltage status.

This check supports the following C-Series Rack Server models providing XML API 2.0 [Cisco UCS Rack-Mount Servers Cisco IMC XML API 2.0]:

- Cisco UCS C220 M5 Rack Server

- Cisco UCS C240 M5 Rack Server

- Cisco UCS C480 M5 Rack Server

- Cisco UCS C480 ML M5 Rack Server

- Cisco UCS C220 M4 Rack Server

- Cisco UCS C240 M4 Rack Server

- Cisco UCS C460 M4 Rack Server

This check does not support the C-Series Rack Server model "Cisco UCS C125 M5 Rack Server Node" which is used as part of a "Cisco UCS C4200 Series Rack Server Chassis".

Check status:

- OK in case the monitored operability status is one of: operable

- WARN in case the monitored operability status is one of: powered-off, removed, identity-unestablishable, bios-post-timeout, disabled, malformed-fru, fabric-unsupported-conn, config, decomissioning, chassis-limit-exceeded, not-supported, discovery

- CRIT in case the monitored operability status is one of: inoperable, degraded, power-problem, voltage-problem, thermal-problem, performance-problem, accessibility-problem, fabric-conn-problem, equipment-problem, peer-comm-problem

- UNKNOWN in ccase the monitored operability status is one of: unknow

Item

{{Rack unit}} followed by the index of the rack followed by {{PSU}} and the index of the PSU

Discovery