Werk #14453: cisco_temperature: Use sensors name instead of description

Komponente Checks & agents
Titel cisco_temperature: Use sensors name instead of description
Datum 13.07.2022
Checkmk Edition Checkmk Raw (CRE)
Checkmk-Version 2.2.0b1
Level Kleine Änderung
Klasse Bugfix
Kompatibilität Kompatibel - benötigt kein manuelles Eingreifen

The check plugin Cisco Devices: Temperature Sensors /cisco_temperature) previously used the entPhysicalDescr MIB instead of the entPhysicalName MIB (.2 and .7 of 1.3.6.1.2.1.47.1.1.1.1 respectively).

On Cisco IOS-XE the entPhysicalDescr MIB and entPhysicalName MIB are identical. However on Cisco IOS-XR all fibre module power levels show "Power Sensor" in entPhysicalDescr, and the unique interface name in entPhysicalName. Before this change IOS-XR would only have a single power sensor called "DOM Power Sensor".