Werk #14453: cisco_temperature: Use sensors name instead of description
Komponente | Checks & agents |
Titel | cisco_temperature: Use sensors name instead of description |
Datum | 13.07.2022 |
Checkmk Edition | Checkmk Raw (CRE) |
Checkmk-Version | 2.2.0b1 |
Level | Kleine Änderung |
Klasse | Bugfix |
Kompatibilität | Kompatibel - benötigt kein manuelles Eingreifen |
The check plugin Cisco Devices: Temperature Sensors /cisco_temperature) previously used the entPhysicalDescr MIB instead of the entPhysicalName MIB (.2 and .7 of 1.3.6.1.2.1.47.1.1.1.1 respectively).
On Cisco IOS-XE the entPhysicalDescr MIB and entPhysicalName MIB are identical. However on Cisco IOS-XR all fibre module power levels show "Power Sensor" in entPhysicalDescr, and the unique interface name in entPhysicalName. Before this change IOS-XR would only have a single power sensor called "DOM Power Sensor".