Werk #15859: cisco_fru_power: Changed behavior for PSUs without power
Komponente | Checks & agents |
Titel | cisco_fru_power: Changed behavior for PSUs without power |
Datum | 17.05.2023 |
Checkmk Edition | Checkmk Raw (CRE) |
Checkmk-Version | 2.1.0p31 2.2.0p6 2.3.0b1 |
Level | Kleine Änderung |
Klasse | Bugfix |
Kompatibilität | Kompatibel - benötigt kein manuelles Eingreifen |
When a PSU monitored by the plugin "Cisco Nexus Switches: State of FRU Power Supplies" had no power, the service went to UNKNOWN. It now goes CRITICAL.
In addition we changed the conditions under which a service is discovered. Powered off FRUs in the following state have not been discovered before, but are now (quoted from the MIB):
offEnvPower(5): FRU is powered off because of power problem in the FRU. For example, the FRU's power translation (DC-DC converter) or distribution failed.
FRUs disabled administratively are no longer discovered:
offAdmin(3): Administratively off.