Werk #15859: cisco_fru_power: Changed behavior for PSUs without power

Komponente Checks & agents
Titel cisco_fru_power: Changed behavior for PSUs without power
Datum 17.05.2023
Checkmk Edition Checkmk Raw (CRE)
Checkmk-Version 2.1.0p31 2.2.0p6 2.3.0b1
Level Kleine Änderung
Klasse Bugfix
Kompatibilität Kompatibel - benötigt kein manuelles Eingreifen

When a PSU monitored by the plugin "Cisco Nexus Switches: State of FRU Power Supplies" had no power, the service went to UNKNOWN. It now goes CRITICAL.

In addition we changed the conditions under which a service is discovered. Powered off FRUs in the following state have not been discovered before, but are now (quoted from the MIB):

offEnvPower(5): FRU is powered off because of power problem in the FRU. For example, the FRU's power translation (DC-DC converter) or distribution failed.

FRUs disabled administratively are no longer discovered:

offAdmin(3): Administratively off.