Check-Manual von aruba_psu_wattage
Aruba 2930M: Power Supply Wattage
Distribution | Official part of Checkmk |
---|---|
Lizenz | GPLv2 |
Unterstützte Agenten | SNMP |
Per default the service goes WARN
/CRIT
if it exceeds the upper levels or falls
below the lower levels configured.
You can either configure absolute levels and percentage levels for both upper and lower levels.
The default absolute upper levels are: WARN
: 500.0W, CRIT
: 600.0W
The default absolute lower levels are: WARN
: 0.0W, CRIT
: 0.0W
The default percentage upper levels are: WARN
: 80.0%, CRIT
: 90.0%
The default percentage lower levels are: WARN
: 0.0%, CRIT
: 0.0%
The check uses the hpicfDcPower-MIB.
Item
The model name combined with the index of the power supply.
Discovery
One service is created for each power supply not in state NotPresent or NotPlugged.