Check-Manual von dell_poweredge_temp
Dell PowerEdge Server: Temperature Sensors
Distribution | Official part of Checkmk |
---|---|
Lizenz | GPLv2 |
Unterstützte Agenten | SNMP |
No limits are set in the check, since limits are configured in the device
itself. The state given by the device is taken as the state of the check
as follows: If the device returns OK
, the check is OK
. If the device returns
other
, unknown
, nonCriticalUpper
and nonCriticalLower
a state of WARN
is returned. Otherwise the check is CRIT
.
The check displays the upper warning and critical limits as configured in the device.
Further limits are not
displayed, even though they may be configured. These are
UpperNonRecoverable, LowerCritical, LowerNonCritical and LowerNonRecoverable.
These limits yet may lead to state changes, the corresponding states are honoured
as outlined above.
Item
Either the name of the location variable configured for the temperature sensor, or the chassis index and sensor index seperated by a dash.
Discovery
One service is created for each temperature sensor if the state setting is not {unknown}.