Werk #4983: brocade_fcport: Fixed wrong speed information
Komponente | Checks & agents | ||||
Titel | brocade_fcport: Fixed wrong speed information | ||||
Datum | 24.07.2017 | ||||
Level | Kleine Änderung | ||||
Klasse | Bugfix | ||||
Kompatibilität | Kompatibel - benötigt kein manuelles Eingreifen | ||||
Checkmk versions & editions |
|
Brocade specific SNMP table .1.3.6.1.4.1.1588.2.1.1.1.6.2.1 does not provide speed information for the interfaces. Thus this check plugins had to fetch another SNMP table .1.3.6.1.2.1.31.1.1.1.15 from IF-MIB. Unfortunately these tables are not directly connected by index and the assumed speed information could be wrong for some devices.
http://community.brocade.com/t5/Fibre-Channel-SAN/SNMP-FC-port-speed/td-p/64980 says that "1073741824" from if-table correlates with index 1 from brocade-if-table.