Check manual page of aruba_psu_wattage

Aruba 2930M: Power Supply Wattage

Distribution Official part of Checkmk
License GPLv2
Supported Agents SNMP
This check monitors the power supply wattage of Aruba 2930M devices.

Per default the service goes WARN/CRIT if it exceeds the upper levels or falls below the lower levels configured.

You can either configure absolute levels and percentage levels for both upper and lower levels.

The default absolute upper levels are: WARN: 500.0W, CRIT: 600.0W The default absolute lower levels are: WARN: 0.0W, CRIT: 0.0W

The default percentage upper levels are: WARN: 80.0%, CRIT: 90.0% The default percentage lower levels are: WARN: 0.0%, CRIT: 0.0%

The check uses the hpicfDcPower-MIB.

Item

The model name combined with the index of the power supply.

Discovery

One service is created for each power supply not in state NotPresent or NotPlugged.