Explore the latest product updates and best practices at our hybrid Checkmk Conference #12 from June 16-18, 2026 – Register here

Check manual page of aruba_sw_temp

Aruba Switch 6100+ series: Temperature

Included in All Checkmk editions
Source Code License Open Source
Supported Agents SNMP

This check monitors the temperature of Aruba 6100+ devices.

For these devices, different temperature thresholds are defined for the different sensors, i.e.,

- CPU / ASIC / PHY: 80°C (WARN), 90°C (CRIT) - DDR: 60°C (WARN), 70°C (CRIT) - PCIE: 55°C (WARN), 60°C (CRIT) - IBC: 45°C (WARN), 50°C (CRIT) - Exhaust: 45°C (WARN), 50°C (CRIT) - Internal: 45°C (WARN), 50°C (CRIT) - DDR Inlet: 40°C (WARN), 45°C (CRIT) - Inlet: 30°C (WARN), 40°C (CRIT) - Board-rear: 45°C (WARN), 50°C (CRIT) - Mainboard and Default (Board-front, Board-NW, Board-W, etc.): 35°C (WARN), 40°C (CRIT)

When a sensor is in a "fault" state, this check is in a "WARN" state. When the sensor is in the "emergency" state, the check is in the "CRIT" state.

The check uses the arubaWiredTempSensorEntry-MIB.

Item

The sensor name.

Discovery

One service is created for each temperature sensor.