Check manual page of cisco_fru_power

Cisco Nexus Switches: State of FRU Power Supplies

Distribution Official part of Checkmk
License GPLv2
Supported Agents SNMP
This check monitors the administrative and operational status of field replaceable unit (FRU) power supplies of Cisco switches. The check is OK when the administrative and operational state is on. The check is CRIT when the administrative state is off or the operational state is offDenied, offEnvPower, offEnvTemp, offEnvFan, failed, or onButInlinePowerFail. The check is WARN otherwise.

Item

The index of the power supply from the list of OIDs for the device, usually starting with {1}.

Discovery

One service is created for each FRU power supply unit. Units are only included if they are not in the operational state {offEnvOther} and {offEnvPower}.