Werk #10286: Netapp API Environment Check: check temperatures, fans, voltages and currents

Component Checks & agents
Title Netapp API Environment Check: check temperatures, fans, voltages and currents
Date Sep 30, 2019
Level Major Change
Class New Feature
Compatibility Compatible - no manual interaction needed
Checkmk versions & editions
2.0.0i1 Checkmk Raw (CRE), Checkmk Enterprise (CEE), Checkmk MSP (CME)

This werk adds the detection and checking of all detected fans, temperature, voltage and current probes. The services (except the fan probes) will monitor the pre-determined high and low levels (for warning and critical) given by the API for each device and {WARN} or {CRIT} if the measured level is too high. To monitor these new services only a service discovery of the host is needed.

For the fans, discrete checks are created which will {CRIT} if the sensor-state differs from "normal".

There is no additional configuration.

To the list of all Werks