Werk #13504: Fix non functional change of OMD config variables for remote sites

Component Setup
Title Fix non functional change of OMD config variables for remote sites
Date Nov 30, 2021
Checkmk Edition Checkmk Raw (CRE)
Checkmk Version 2.1.0b1
Level Trivial Change
Class Bug Fix
Compatibility Compatible - no manual interaction needed

If you changed sitespecific settings for remote sites that depend on the "omd config" command (like "Start during system boot", "Access to Livestatus via TCP", etc.), the changes were not correctly applied on the effected remote sites.

This behaviour affects at least all versions since 1.5.

If you change such settings now, the "Activate pending changes page" will show the following warning for each effected site: "The applied changes require a restart of all site services. These are performed now and will cause a short offline period."

On activating changes, a background job will be started on the remote site to change the choosen settings. This background job needs to stop and start the site, what causes a short offline period on the remote site.