Werk #15859: cisco_fru_power: Changed behavior for PSUs without power
Component | Checks & agents | ||||||||
Title | cisco_fru_power: Changed behavior for PSUs without power | ||||||||
Date | May 17, 2023 | ||||||||
Level | Trivial Change | ||||||||
Class | Bug Fix | ||||||||
Compatibility | Compatible - no manual interaction needed | ||||||||
Checkmk versions & editions |
|
When a PSU monitored by the plugin "Cisco Nexus Switches: State of FRU Power Supplies" had no power, the service went to UNKNOWN. It now goes CRITICAL.
In addition we changed the conditions under which a service is discovered. Powered off FRUs in the following state have not been discovered before, but are now (quoted from the MIB):
offEnvPower(5): FRU is powered off because of power problem in the FRU. For example, the FRU's power translation (DC-DC converter) or distribution failed.
FRUs disabled administratively are no longer discovered:
offAdmin(3): Administratively off.