Werk #2062: grouped interfaces: additional information in check output and new port state 'degraded'

Component Checks & agents
Title grouped interfaces: additional information in check output and new port state 'degraded'
Date Mar 20, 2015
Checkmk Edition Checkmk Raw (CRE)
Checkmk Version 1.2.7i1
Level Trivial Change
Class New Feature
Compatibility Incompatible - Manual interaction might be required

Grouped interfaces now clearly show that they are grouped together by listing all group members and their state in the check output.

Additionally the new port state degraded has been introduced. A grouped interface is set to this port state if not all of its members are up. If all members of a group are down, the grouped interface is also considered down, as usual.

CRIT - Group Status (degraded)(!!), Members: [QLogic 1 10GbE Adapter 2 (down), QLogic 1 10GbE Adapter (up)] 10.00 Gbit/s (wrong speed, expected: 20.00 Gbit/s)(!), in: 0.00 B/s, out: 0.00 B/s