Werk #22299: Entity sensors: don't crash on sensors without a sensor type

Component Checks & agents
Title Entity sensors: don't crash on sensors without a sensor type
Date Sep 25, 2026
Level Trivial Change
Class Bug Fix
Compatibility Compatible - no manual interaction needed
Checkmk versions & editions
3.0.0b1
Not yet released
Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT
2.5.0p15
Not yet released
Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT
2.4.0p38
Not yet released
Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT

This werk affects SNMP devices that are monitored through the ENTITY-SENSOR-MIB, such as Palo Alto, Cisco ASA, Arista and Cisco Firepower devices.

Some devices report sensors without a sensor type, for example the sensors of a transceiver slot. In this case the section entity_sensors crashed with KeyError: '', and the services Temperature, Fan and Power of the whole device got no data.

Checkmk now skips sensors without a known sensor type and monitors all other sensors of the device as before.