Werk #22521: netgear_powersupplies: Report unknown power supply states instead of crashing

Component Checks & agents
Title netgear_powersupplies: Report unknown power supply states instead of crashing
Date Sep 29, 2026
Level Trivial Change
Class Bug Fix
Compatibility Compatible - no manual interaction needed
Checkmk versions & editions
3.0.0b1
Not yet released
Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT
2.5.0p15 Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT

If a Netgear switch reported a power supply state that Checkmk does not know (seen: 11), the Power Supply <item> service crashed with KeyError: '11'.

The service now goes UNKNOWN and shows the state value the device sent, e.g. Status: unknown state '11' (expected 1, 2 or 3), so you can look it up in the documentation of your device.