Catch up on the latest product updates, best practices, and expert insights from the Checkmk Conference #12 – Watch the livestream recordings now

Werk #22549: Redfish PSU: accept voltage with unit

Component Checks & agents
Title Redfish PSU: accept voltage with unit
Date Oct 5, 2026
Level Trivial Change
Class Bug Fix
Compatibility Compatible - no manual interaction needed
Checkmk versions & editions
3.0.0b1
Not yet released
Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT
2.5.0p16
Not yet released
Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT
2.4.0p38
Not yet released
Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT

Some Redfish BMCs report the line input voltage of a power supply as text with a unit, for example 220V, instead of a number. The "Power supply" service then crashed with ValueError: could not convert string to float: '220V'.

A trailing "V" is now accepted, so such power supplies report their input voltage as usual. Any other value that is not a number is shown as UNKNOWN with the value the device sent, while input power, output power and capacity are still reported.

To the list of all Werks