Werk #22859: EC: messages can't stop the housekeeping

Component Event Console
Title EC: messages can't stop the housekeeping
Date Oct 23, 2026
Level Trivial Change
Class Bug Fix
Compatibility Compatible - no manual interaction needed
Checkmk versions & editions
3.0.0b1
Not yet released
Checkmk Community, Checkmk Pro, Checkmk Ultimate, Checkmk Cloud, Checkmk Ultimate MT

Syslog messages sent to the Event Console can carry structured data of Checkmk, e.g. [Checkmk@18662 sl="10" ipaddress="192.0.2.1"], which Checkmk itself uses to pass on the host name, the application, the service level and the IP address of a message. The Event Console, however, took over any parameter of it as a field of the event, e.g. its lifetime, its phase or its ID. A single message setting such a field to an unexpected value could stop the housekeeping of the Event Console: With e.g. live_until="tomorrow", every housekeeping run failed with an error in var/log/mkeventd.log until the event was archived, even after a restart. Meanwhile, e.g. delayed events didn't open, and the Event Console didn't notice missing expected messages.

The Event Console now only takes over the parameters which Checkmk itself sends: host, application, pid, msg_id, ipaddress and sl. It ignores any other parameter.