Check-Manual von cisco_fru_power

Cisco Nexus Switches: State of FRU Power Supplies
Distribution offizieller Teil von Check_MK
Lizenz GPL
Unterstützte Agenten SNMP

This check monitors the administrative and operational status of field replaceable unit (FRU) power supplies of Cisco switches. The check is OK when the administrative and operational state is {on}. The check is CRIT when the administrative state is {off} or the operational state is {offDenied}, {offEnvPower}, {offEnvTemp}, {offEnvFan}, {failed}, or {onButInlinePowerFail}. The check is WARN otherwise.

Item

The index of the power supply from the list of OIDs for the device, usually starting with {1}.

Discovery

One service is created for each FRU power supply unit. Units are only included if they are not in the operational state {offEnvOther} and {offEnvPower}.