Check-Manual von hp_proliant_da_phydrv
HP Proliant Servers: Physical Drives in Drive Arrays | |
---|---|
Distribution | offizieller Teil von Check_MK |
Lizenz | GPL |
Unterstützte Agenten | SNMP |
This check connects to the SNMP agent installed on an operating system on a HP Proliant server and reads the information from the {CPQIDA-MIB} MIB. The systems SNMP agent is extended by the HP Management Agents which need to be installed on the monitored systems. The check monitors the reported state of the physical drives connected to the internal drive arrays of HP Proliant Servers. This check has been developed with ProLiant BL460c G1 systems but should work on other HP Proliant Servers too.
Item
The index of the controller and index of the drive seperated by a {{/}}
Discovery
One service is created for each physical drive.