Check-Manual von ibm_svc_enclosure

IBM SVC / Storwize V3700 / V7000: Status of Enclosures, Canisters and PSUs
Distribution offizieller Teil von Check_MK
Lizenz GPL
Unterstützte Agenten Ibm_Svc

Checks the status of Enclosures, Canisters and PSUs in an IBM SVC / Storwize V3700 / V7000 device. Check status: In case the WATO rule {IBM SVC Enclosure} is not configured the check status is {OK} if the enclosure reports status {online} and all canisters and PSUs are online and {CRIT} otherwise. If the firmware supports it then also fan modules are being checked. In case the WATO rule {IBM SVC Enclosure} is configured the check status for the canisters is {WARN} or {CRIT} according to the configured lower levels for the number of online canisters. Please note: You need the special agent {agent_ibmsvc} for retrieving the monitoring data from the device. Your monitoring user must be able to SSH to the device with SSH Key Authentification. Please exchange SSH key. The special agent itself can be configured by WATO.

Item

The ID of the enclosure.

Discovery

One service is created for each enclosure.