Check-Manual von netapp_ontap_environment_temperature

NetApp Filer Clustermode: System Temperature

Distribution Official part of Checkmk
Lizenz GPLv2
Unterstützte Agenten Netapp
This check monitors the temperature of various components of a NetApp filer.

The checks reports CRIT when the sensor-value is higher than the critical-high-threshold, and reports WARN if it is higher than the warning-high-threshold. If both critical-high-threshold and warning-high-threshold are present the check will also honor critical-low-threshold and warning-low-threshold if present and the threshold-sensor-value falls below those.

Please note: You need the Special Agent "NetApp via ONTAP REST Api" to retrieve the monitoring data from the device. The Special Agent itself can be configured by WATO.

Item

Name of the temperature sensor

Discovery

One service is created for each sensor reporting temperature information.