Check-Manual von perle_modules_cm1110

Perle Mediaconverter: CM 1110 Modules States

Distribution Official part of Checkmk
Lizenz GPLv2
Unterstützte Agenten SNMP
This check monitors the power state and fiber and copper LPRF and link status of CM 1110 modules of Perle Meadiconverter devices which support the PERLE-MCR-MGT MIB.

The check reports CRIT if no power to module. Otherwise it is OK.

The check is OK if the fiber and copper link states are UP. Otherwise the check goes CRIT.

If the fiber LPRF state is OK the check is OK. If it is OFFLINE, link fault, auto neg error or not applicable, the check goes CRIT.

If the copper LPRF state is OK the check is OK. Otherwise, in case of remote fault, the check goes CRIT.

Item

The name of the module

Discovery

One service is created for each module.